📄 Download SFS Catalogue (PDF) Request Safety Audit →

Turnkey Fire Engineering Services.

From supply, hydraulic layout modeling, and installation to hydrostatic refilling and 24/7 Annual Maintenance Contracts (AMC), we cover every layer of industrial fire safety.

01
SERVICE 01 / FIRE SUPPRESSION

Fire Extinguisher Supply & Certified Mounting

Live Spec →

Complete Fire Extinguisher Lineup & Precision Wall Installation

We supply an extensive lineup of BIS-certified and ISI-marked fire extinguishers engineered to tackle Class A, B, C, D, K, and Electrical hazards. All units undergo factory pressure testing and come equipped with heavy-duty mounting hardware and pressure gauges.

✓ ABC Dry Chemical Powder (Stored Pressure)
✓ Carbon Dioxide (CO2) for Live Electrical Panels
✓ Mechanical AFFF Foam for Flammable Liquid Storages
✓ Clean Agent (HFC-227ea / Novec) for High-Value Equipment
⚡ Technical Telemetry BIS Active
Compliance Standard IS 15683 / NFPA 10
Discharge Range 4 to 6 Meters
Factory Test Pressure 30 to 35 Bar
Deployment Rating Class A, B, C, D, K
02
SERVICE 02 / HYDROSTATIC TESTING

Extinguisher Refilling & Hydrostatic Bay

Live Spec →

High-Pressure Hydrostatic Recertification & Gas Refilling

Ensuring your existing fire extinguishers remain 100% operational through certified refilling, high-pressure hydrostatic cylinder testing, valve replacements, and tamper-evident sealing per IS 2190 protocols.

✓ 300 Bar Hydrostatic Pressure Testing Bay
✓ Pure Monoammonium Phosphate & Medical Grade CO2 Gas
✓ On-Site Refilling Mobile Vans for Large Campuses
✓ Digital Hydro-Test Certification for Fire Audits
⚡ Testing Protocol IS 2190 Certified
Hydro Test Pressure Up to 300 Bar
Express Turnaround 24 to 48 Hours
Gas Purity Standard 99.9% Pure CO2 / MAP 90
Audit Documentation QR Code Digital Certificate
03
SERVICE 03 / EARLY DETECTION

Microprocessor Addressable Fire Alarm Networks

Live Spec →

Sub-Second Multi-Sensor Detection & Automated Evacuation

Intelligent early-warning addressable fire alarm panels with multi-sensor smoke, thermal, and flame detectors. Real-time pin-point zone identification, automatic voice evacuation broadcasts, and BMS integration.

✓ Addressable & Conventional Alarm Panels (1 to 8 Loops)
✓ Optical Smoke, Rate-of-Rise Heat, and Flame UV/IR Detectors
✓ Manual Call Points, Electronic Sounders & Strobe Beacons
✓ Lift Recall, AHU Trip & Fire Door Release Relays
⚡ Sensor Telemetry Loop Online
System Protocol EN 54 / NFPA 72 Compliant
Loop Response Speed < 1.5 Seconds
Device Capacity Up to 2,048 Address Points
BMS Integration BACnet / Modbus / RS485
04
SERVICE 04 / HYDRAULIC POWER

Heavy-Duty Fire Pump House & Hydrant Ring Mains

Live Spec →

4,500 LPM High-Capacity Pump Sets & Ring Main Networks

Engineering turnkey diesel engine main fire pumps, electric booster pumps, jockey pumps, and external ring main hydrant networks capable of delivering 4,500 LPM at 12.5 Bar line pressure during emergency scenarios.

✓ NFPA 20 Compliant Electric & Diesel Driven Fire Pumps
✓ Internal Hydrant Valves, Hose Reel Drums & RRL Hoses
✓ Underground Ring Main Ductile Iron / MS Pipeline Networks
✓ Automatic Pressure Switch & Engine Starter Panels
⚡ Hydraulic Specs 12.5 Bar Primed
Peak Discharge Flow 4,500 LPM (1,200 GPM)
Line Test Pressure 16 Bar Hydrostatic
Engine Failover Speed Under 8 Seconds
Standard Compliance NFPA 20 / NBC 2016 Part 4
05
SERVICE 05 / WATER MIST GRID

Automatic Ceiling Sprinkler Grids

Live Spec →

Targeted Thermal Suppression & Hydraulic Flow Optimization

High-performance quartz bulb sprinkler networks designed for high-rises, warehouses, and shopping malls. Fast-response thermal bulbs discharge high-pressure localized mist to extinguish flame origins instantly.

✓ Pendant, Upright, and Concealed Sprinkler Heads (68°C to 141°C)
✓ Alarm Check Valves, Water Motor Gongs & Flow Switches
✓ Pre-Action & Deluge Systems for Cold Storages & Atriums
✓ Hydraulic Calculation Modeling for Optimal Water Coverage
⚡ Grid Parameters NFPA 13 Standard
Bulb Trigger Ratings 68°C / 79°C / 93°C / 141°C
Discharge Coefficient K-5.6 / K-8.0 / K-11.2 (ESFR)
System Architectures Wet, Dry, Pre-Action, Deluge
Flow Switch Alert Real-time Zone Annunciation
06
SERVICE 06 / MISSION-CRITICAL PROTECTION

Clean Agent FM-200 & Novec Flooding Systems

Live Spec →

Sub-10s Total Gas Flooding for Data Centers & Server Racks

Specialized gas suppression engineered specifically for critical mission rooms: data centers, telecom server rooms, server racks, MRI scan rooms, and museum archives where water would cause irreversible equipment damage.

✓ FM-200 (HFC-227ea) and Novec 1230 Gas Cylinders
✓ Sub-10 Second Full Chamber Flooding Discharge
✓ Electrically Non-Conductive, Zero Residue, Zero Ozone Depletion
✓ Cross-Zoned Optical Sensors & Abort Switch Units
⚡ Gas Telemetry NFPA 2001 Standard
Discharge Speed < 10 Seconds Full Room Flood
Environmental Impact Zero ODP (Ozone Safe)
Personnel Safety NOAEL Safe for Occupied Rooms
Actuation System Solenoid & Manual Release Key

Ready to Upgrade Your Building's Safety?

Contact our senior fire protection engineers for site inspections, hydraulic calculations, equipment refilling, or Annual Maintenance Contracts (AMC).

⚡ Get Free Site Audit
WhatsApp WhatsApp Chat Facebook Facebook Instagram Instagram Call Us Call +91 92019 63109